Cleanroom Testing FAQ
Get answers to the most common questions about cleanroom testing, classification, and certification. Our experts have compiled this comprehensive FAQ based on questions from clients across Israel's pharmaceutical, biotech, semiconductor, and medical device industries.
ISO 14644-1 classifies cleanrooms based on the maximum permitted concentration of airborne particles. The classification ranges from ISO Class 1 (cleanest) to ISO Class 9. For example, ISO Class 5 (equivalent to the old Class 100) allows maximum 3,520 particles ≥0.5μm per cubic meter. Most pharmaceutical cleanrooms operate at ISO Class 5-8, while semiconductor fabs may require ISO Class 1-3.
Testing frequency depends on the cleanroom classification and regulatory requirements. ISO 14644-2 recommends maximum time intervals: ISO Class 5 and cleaner should be tested every 6 months for particle counts, while ISO Class 6-9 can be tested annually. However, pharmaceutical GMP facilities often require more frequent testing—monthly or quarterly—based on risk assessment. Critical parameters like pressure differentials should be monitored continuously.
'At rest' testing is performed when the cleanroom is complete and operational but without production activity or personnel. 'In operation' testing occurs during normal production with equipment running and personnel present. Both states are defined in ISO 14644-1 and EU GMP Annex 1. Pharmaceutical facilities typically must meet their classification in both states, with 'in operation' being the more challenging condition.
A comprehensive cleanroom certification typically includes: particle count testing per ISO 14644-1, airflow velocity and uniformity testing, air change rate calculations, HEPA/ULPA filter integrity testing (DOP/PAO), room pressure differential testing, temperature and humidity verification, recovery time testing, and lighting level measurements. Additional tests may include sound level, vibration, and electrostatic discharge (ESD) testing depending on the application.
HEPA filter integrity testing verifies that filters are properly installed and have no leaks. The test uses an aerosol challenge (typically DOP or PAO) upstream of the filter while scanning the downstream face and frame seals with a photometer. Any penetration above 0.01% indicates a leak requiring repair or filter replacement. This test is critical because even small leaks can compromise cleanroom classification and allow contaminants into the controlled environment.
Pressure differentials create a hierarchy that prevents contamination migration. Cleaner areas are maintained at higher pressure than adjacent less-clean areas, so when doors open, air flows from clean to less clean. Typical differentials are 10-15 Pa (0.04-0.06 inches WC) between cleanroom grades. For containment applications (like potent compounds), negative pressure is used instead. Continuous monitoring with alarms is recommended for critical applications.
Our comprehensive testing reports include: executive summary with pass/fail status, detailed methodology per ISO standards, all raw data and calculations, room drawings showing sample locations, equipment calibration certificates, HEPA filter scan results with leak locations if any, trending data compared to previous tests, non-conformance reports with remediation recommendations, and certificates of compliance. Reports are provided in both hard copy and digital format.
Yes, many tests can be performed during normal operations. 'In operation' classification testing is actually required by GMP regulations. However, some tests like HEPA filter integrity testing are best performed 'at rest' for accurate results. We work with clients to schedule testing during planned maintenance windows or shift changes to minimize production impact. Weekend and off-hours testing is available for facilities with continuous operations.
Duration depends on cleanroom size and scope of testing. A small ISO Class 7 cleanroom (under 100 m²) with standard tests typically takes 1-2 days. Larger facilities or those requiring extensive testing (ISO Class 5 or better, pharmaceutical GMP) may require 3-5 days or more. We provide detailed schedules during the proposal phase. Expedited testing is available for urgent requirements with appropriate resource allocation.
Our technicians hold certifications from recognized bodies such as IEST (Institute of Environmental Sciences and Technology) and have training in ISO 14644 standards, pharmaceutical GMP requirements, and industry-specific protocols. They maintain current knowledge through continuing education and participate in proficiency testing programs. All testing equipment is calibrated to NIST-traceable standards with current calibration certificates.